EORT/HASS Integrated Environment Testing Chamber

  • Product introduction:EORT-V Chamber has been admired by most advanced industries since its birth, and the users are very satisfied with the results of the EORT-V Chamber screening of product defect rate. Through the analysis of the screening data, they believe that the product will change the temperature and humidity ...
Product details

Product introduction


EORT-V Chamber has been admired by most advanced industries since its birth, and the users are very satisfied with the results of the EORT-V Chamber screening of product defect rate. Through the analysis of the screening data, they believe that the product will change the temperature and humidity quickly, and Under the comprehensive test of multi-axis vibration, the service life and potential defects of the product at the beginning of production or development can be screened out, because the defects can be quickly exposed under the combined action of temperature and mechanics. Reduced the defective rate of the products, making the products of the company more competitive in the same industry. EORT-V Chamber is more and more recognized and valued by more similar industries such as electronics, netcom, etc.


Specifications


Volume

512L

Inner size

W800 mm×D800 mm×H800 mm

Outer size

According to drawings

Weight

1650 Kg

Test environmental conditions

The ambient temperature is + 25 ° C, the relative humidity is ≤85%, and there is no sample in the test chamber.

Test method

GB/T 5170.2—1996 Temperature test equipment

GB/T 5179.2—1996 Humidity test equipment

Temp. range

-50℃150℃

Hum. range

15% ~ 98%RH

Control accuracy

a. Temp 0.01℃

b. Hum±0.1%RH

Uniformity

a. Temp±2.0℃

b. Hum+2.0%RH or-3.0%RH

Stability

a. Temp±0.3℃

b. Hum±2%RH

Pre-heating temp. range

+RT~+150℃

Heating time

30min, Note: The temperature rise time is the performance when the heat storage zone operates alone.

Pre-cooling temp. range

-20℃ ~ -70℃

Cooling time

70 min, Note: The cooling time is the performance when the low temperature area is operated alone

Impact test method

Pneumatic damper switching

Temp. impact condition

+25℃→+45℃1min

+45℃→+65℃1min

+65℃→+45℃1min

+45℃→-5℃2min

-5℃→-25℃1min

-25℃→+10℃1min

Stabilization time of heating  impact

5min

Stabilization time of cooling  impact

8min

Hum. range

20%RH - 98%RH

Relative humidity deviation

±3.0%RH (Hum75%RH)

±5.0%RH (Hum≤75%RH)